Summary for Test 2022-08-29-54-7
Test performed: AASHTO T30-19Project Information
Project Identifiers | Project ID: 993299 DEA: 022J3904 EFIS: 0221000073 |
---|---|
DIST-CO-RTE-PM | 02-SHA-44-45.5/51.6 |
Award Date | 11/16/2021 |
Closeout Date | 11/23/2022 |
Work Description | HMA OVERLAY, REPLACE AC SURFACING AND SHOULDER BACKING. |
Location Description | SHASTA COUNTY NEAR VIOLA FROM 3.0 MILES EAST OF DEER FLAT ROAD TO 0.5 MILE EAST OF BRIDGE CREEK ROAD |
QA Service Level | 1 (Verified on 10/18/2021) |
Sample Information
Sample Taken Date | 08/29/2022 | Sample Unique Key | 54 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/29/2022 |
Sample type | Acceptance | A brief description of the sample | 16 boxes of Lime Treated 1/2-inch Type A HMA-A with 25.0% RAP and virgin PG 58-22 from Valero – Benecia |
The quantity of what the sample constitutes | Production Start Up-Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | D79142 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Tullis – Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 866064 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-08-29-54
DIME Test ID: 2022-08-29-54-7
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2022-09-09
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Calculated
Tester's full name: Arthur Mills
Date of test: 08/31/2022
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 99 %
Cumulative percent passing the 1/2 in. sieve: 93 %
Cumulative percent passing the 3/8 in. sieve: 79 %
Cumulative percent passing the #4 sieve: 55 %
Cumulative percent passing the #8 sieve: 36 %
Cumulative percent passing the #16 sieve: 25 %
Cumulative percent passing the #30 sieve: 17 %
Cumulative percent passing the #50 sieve: 13 %
Cumulative percent passing the #100 sieve: 9 %
Cumulative percent passing the #200 sieve: 7.3 %
General comments (publicly viewable) (Max 1000 characters): Corrected Post Plant Gradation.
Specimen is coarse on the 3/4-inch sieve.
Test was verified on 9/9/2022 ✔