Summary for Test 2022-08-13-11-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Sample Information

Sample Taken Date08/13/2022 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/13/2022
Sample typeQuality Assurance A brief description of the sample1 x 4 PCC Aggregate and Sand
The quantity of what the sample constitutes3 bags From where was the sample collectedDistributor
First name of sampler or witnessed bylarry Last name of sampler or witnessed byfrancisco
Title of samplerTE Telephone number of sampler
Laboratory sample identificationtest 1 30tons out at 2315 PM Linked DIME Sample ID
The fabricator/manufacturer/facility nameLANEsecurity paving Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0040
The fabricator's/manufacturer's product name for the sampleLANE SECURITY PAVING The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedAt the plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design number1610974 Lot number
Sublot number Aggregate Mix NumberNot set

Combined Gradation Report Information

Combined Gradation Report IdBin IndexDime Test Id
No assigned tests for this sample.

Test Details

DIME Sample ID: 2022-08-13-11
DIME Test ID: 2022-08-13-11-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2022-08-22

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: tony price
Date of test: 08/16/2022
Cumulative percent passing the 2 in. sieve: 0 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 97 %
Cumulative percent passing the 3/4 in. sieve: 77 %
Cumulative percent passing the 1/2 in. sieve: 0 %
Cumulative percent passing the 3/8 in. sieve: 34 %
Cumulative percent passing the #4 sieve: 8 %
Cumulative percent passing the #8 sieve: 4 %
Cumulative percent passing the #16 sieve: 70 %
Cumulative percent passing the #30 sieve: 48 %
Cumulative percent passing the #50 sieve: 25 %
Cumulative percent passing the #100 sieve: 10 %
Cumulative percent passing the #200 sieve: 4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/22/2022