Summary for Test 2022-06-22-1-2
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 214590 DEA: 043G4744 EFIS: 0412000074 |
---|---|
DIST-CO-RTE-PM | 04-MRN,MRN-580-6.9/7.8,0.0/2.5 |
Award Date | 01/14/2021 |
Closeout Date | Not set |
Work Description | CLEAN AND PAINT STRUCTURAL STEEL BRIDGE. |
Location Description | CONTRA COSTA AND MARIN COUNTIES IN RICHMOND AND SAN RAFAEL FROM 0.8 MILE WEST OF TOLL PLAZA TO 0.1 MILE EAST OF MAIN STREET |
QA Service Level | 1 (Verified on 02/18/2020) |
Sample Information
Sample Taken Date | 06/22/2022 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/26/2022 |
Sample type | Acceptance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 26 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
Title of sampler | QA Consultant | Telephone number of sampler | 415-608-1742 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-071-22 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 5362-01 |
---|---|---|---|
Heat Number(s) | 100798818, 8000008882, C72845 | Nut Mfg. Lot Number(s) | 453592A |
Washer Mfg. Lot Number(s) | 138599 | Bolt Specification | A325 |
Bolt Length(s) | 3.0" | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 428683A |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2022-06-22-1
DIME Test ID: 2022-06-22-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2022-08-05
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 07/29/2022
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 72167 | A563 HDG Nut Proof Load |
General comments (publicly viewable) (Max 1000 characters): A563 HDG Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 8/5/2022 ✔