Summary for Test 2022-07-25-17-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 215221
DEA: 07332604
EFIS: 0716000287
DIST-CO-RTE-PM07-LA-10-R12.4/14.9
Award DateNot set
Closeout DateNot set
Work DescriptionREMOVE RAISED ISLAND, CONSTRUCT CONCRETE BARRIER AND INSTALL LIGHTING.
Location DescriptionTHE COUNTY AND CITY OF LOS ANGELES FROM 0.1 MILE EAST OF ARLINGTON AVENUE OVERCROSSING TO 0.7 MILE EAST OF ROUTE 10/110 SEPARATION
QA Service Level1 (Verified on 03/19/2021)

Sample Information

Sample Taken Date07/25/2022 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/26/2022
Sample typeAcceptance A brief description of the sampleAggregate Base
The quantity of what the sample constitutes507 sq. yd. From where was the sample collectedJob Site
First name of sampler or witnessed byPhilip Last name of sampler or witnessed byMaquiran
Title of samplerMREA Telephone number of sampler2133581518
Laboratory sample identification22-1926 Linked DIME Sample ID
The fabricator/manufacturer/facility nameChumo Construction Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedFrom various locations at Aggregate Base
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2022-07-25-17
DIME Test ID: 2022-07-25-17-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-07-26

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 07/25/2022
Sum of Count or Density: 5.93 g/cc
Average of Count or Density: 1.98 g/cc
Sum of Moisture Count: 0.51 g/cc
Average of Moisture Count: 0.17 g/cc
Calculated Percent Relative Compaction: 95.2 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/26/2022