Summary for Test 2016-07-21-7-3
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 210871 DEA: 044G4604 EFIS: 0412000480 |
---|---|
DIST-CO-RTE-PM | 04-MRN-101-1.5/14.0 |
Award Date | 01/28/2016 |
Closeout Date | 10/17/2019 |
Work Description | REMOVE EXISTING AND CONSTRUCT NEW BRIDGE RAILINGS. |
Location Description | IN MARIN COUNTY, AT VARIOUS LOCATION, FROM SPENCER AVE OVERCROSSING TO NORTH BRANCHGALLINAS CREEK BRIDGE |
QA Service Level | 1 (Verified on 01/12/2016) |
Sample Information
Sample Taken Date | 07/21/2016 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2016 |
Sample type | Quality Assurance | A brief description of the sample | End Anchors |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Source |
First name of sampler or witnessed by | ED | Last name of sampler or witnessed by | Fleming |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Dextra America Nucor | Transportation Laboratory (TL) Number | C715251 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B1029516 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | PL16102737 | Head Manufacturer Lot Number(s) | 4008 |
Rebar Size | #6 | Headed Bar Model Name | Bartec |
Size of Head | Full Size - 9x | Head Connection Type | Threaded |
Head Shape | Circular | Rebar Manufacturer | Nucor |
Head Manufacturer | Dextra | Head Fabricator | Dextra |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2016-07-21-7
DIME Test ID: 2016-07-21-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2016-07-26
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/25/2016
UTM: 400KIP
Temperature: 72 F
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 29 | 0.44 | 42810 | 97300 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/26/2016 ✔