Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2016-07-21-7
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 210871 DEA: 044G4604 EFIS: 0412000480 |
---|---|
DIST-CO-RTE-PM | 04-MRN-101-1.5/14.0 |
Award Date | 01/28/2016 |
Closeout Date | 10/17/2019 |
Work Description | REMOVE EXISTING AND CONSTRUCT NEW BRIDGE RAILINGS. |
Location Description | IN MARIN COUNTY, AT VARIOUS LOCATION, FROM SPENCER AVE OVERCROSSING TO NORTH BRANCHGALLINAS CREEK BRIDGE |
QA Service Level | 1 (Verified on 01/12/2016) |
Sample Information
Sample Taken Date | 07/21/2016 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2016 |
Sample type | Quality Assurance | A brief description of the sample | End Anchors |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Source |
First name of sampler or witnessed by | ED | Last name of sampler or witnessed by | Fleming |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Dextra America Nucor | Transportation Laboratory (TL) Number | C715251 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B1029516 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | PL16102737 | Head Manufacturer Lot Number(s) | 4008 |
Rebar Size | #6 | Headed Bar Model Name | Bartec |
Size of Head | Full Size - 9x | Head Connection Type | Threaded |
Head Shape | Circular | Rebar Manufacturer | Nucor |
Head Manufacturer | Dextra | Head Fabricator | Dextra |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2016-07-21-7-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-07-21-7-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-07-21-7-3 ASTM A970-15e1 (Verified)