Summary for Test 2022-06-28-37-1
Test performed: CTM 521-June 2012Project Information
Project Identifiers | Project ID: 215221 DEA: 07332604 EFIS: 0716000287 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-R12.4/14.9 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | REMOVE RAISED ISLAND, CONSTRUCT CONCRETE BARRIER AND INSTALL LIGHTING. |
Location Description | THE COUNTY AND CITY OF LOS ANGELES FROM 0.1 MILE EAST OF ARLINGTON AVENUE OVERCROSSING TO 0.7 MILE EAST OF ROUTE 10/110 SEPARATION |
QA Service Level | 1 (Verified on 03/19/2021) |
Sample Information
Sample Taken Date | 06/28/2022 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/29/2022 |
Sample type | Acceptance | A brief description of the sample | 6x12 LCB cylinders |
The quantity of what the sample constitutes | 250 yd3 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Rosauro | Last name of sampler or witnessed by | Nogoy |
Title of sampler | TEC | Telephone number of sampler | 2137939321 |
Laboratory sample identification | 22-1595 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Robertson's | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | SC270N31 |
---|---|---|---|
The truck number from where the sample was collected | 1371 | The batch plant ticket number from where the sample was collected | 7145924 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Discharge from concrete truck into wheelbarrow. | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-06-28-37
DIME Test ID: 2022-06-28-37-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-07-10
Test Results
Number of specimens: 2
Input Type: Calculated
Tester's full name: Rosauro Nogoy
Date of test: 07/05/2022
Correction factor: 1
Cylinder Age: 7 days
Break Description of Cylinder 1 (if not 'cone'): 2
Break Description of Cylinder 2 (if not 'cone'): 3
Average Compressive Strength (to nearest 10): 800 lb/in^2
Compressive Strength of Cylinder 1: 790 lb/in^2
Compressive Strength of Cylinder 2: 800 lb/in^2
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/10/2022 ✔