Summary for Test 2022-06-22-18-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993241
DEA: 101F7604
EFIS: 1017000024
DIST-CO-RTE-PM10-SJ-12-R4.4
Award Date11/05/2021
Closeout Date05/10/2023
Work DescriptionREPLACE BRIDGE BEARING PADS.
Location DescriptionSAN JOAQUIN COUNTY IN TERMINOUS AT LITTLE POTATO SLOUGH BRIDGE
QA Service Level1 (Verified on 09/27/2021)

Sample Information

Sample Taken Date06/22/2022 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/23/2022
Sample typeQuality Assurance A brief description of the sampleBar Lock Couplers
The quantity of what the sample constitutes150 Couplers From where was the sample collectedJob Site
First name of sampler or witnessed byD Last name of sampler or witnessed byLaureno
Title of samplerSR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCEC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelBar-Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)MM20102408 Rebar Heat Number(s)6031479
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2022-06-22-18
DIME Test ID: 2022-06-22-18-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2022-06-27

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 06/27/2022
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 5/16mm1-0.00240.3132300104194service splicespaine

General comments (publicly viewable) (Max 1000 characters): service splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 6/27/2022