Summary for Test 2022-06-01-1-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 214989 DEA: 050L7224 EFIS: 0515000098 |
---|---|
DIST-CO-RTE-PM | 05-SLO-1-34.5 |
Award Date | 10/13/2021 |
Closeout Date | Not set |
Work Description | REPLACE BRIDGE. |
Location Description | SAN LUIS OBISPO COUNTY NEAR MORRO BAY AT OLD CREEK BRIDGE |
QA Service Level | 1 (Verified on 09/03/2020) |
Sample Information
Sample Taken Date | 06/01/2022 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/06/2022 |
Sample type | Quality Assurance | A brief description of the sample | Ultimate Welded Hoops |
The quantity of what the sample constitutes | 985 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | QA Inspector | Telephone number of sampler | 213 435 4055 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-089-22 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 111122 |
Hoop Manufacturer Lot Number(s) | 1, 3 and 7 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #5 |
Diameter of Hoop | 2'-0" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2022-06-01-1
DIME Test ID: 2022-06-01-1-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2022-06-09
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 06/08/2022
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 3 | 5/16mm | 0.31 | 28753.77 | 92754 | ok necking | spaine |
General comments (publicly viewable) (Max 1000 characters): ok necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 6/9/2022 ✔