Summary for Test 2022-04-09-1-2
Test performed: CTM 216-June 2011Project Information
| Project Identifiers | Project ID: 215221 DEA: 07332604 EFIS: 0716000287 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-R12.4/14.9 |
| Award Date | 12/16/2020 |
| Closeout Date | 11/25/2024 |
| Work Description | REMOVE RAISED ISLAND, CONSTRUCT CONCRETE BARRIER AND INSTALL LIGHTING. |
| Location Description | THE COUNTY AND CITY OF LOS ANGELES FROM 0.1 MILE EAST OF ARLINGTON AVENUE OVERCROSSING TO 0.7 MILE EAST OF ROUTE 10/110 SEPARATION |
| QA Service Level | 1 (Verified on 03/19/2021) |
Sample Information
| Sample Taken Date | 04/09/2022 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/09/2022 |
| Sample type | Department Acceptance | A brief description of the sample | Subgrade |
| The quantity of what the sample constitutes | 215 yd2 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Rosauro | Last name of sampler or witnessed by | Nogoy |
| Title of sampler | TEC | Telephone number of sampler | 2137939321 |
| Laboratory sample identification | 22-0756 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | N/A | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Subgrade | A detailed description of where the material sample was collected | From various locations at subgrade. |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2022-04-09-1
DIME Test ID: 2022-04-09-1-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2022-04-14
Test Results
Is oversize material: No
Input Type: Calculated
Tester's full name: Rosauro Nogoy
Date of test: 04/09/2022
In-place wet density: 2.14
Highest adjust wet density: 2.24
% Moisture: 8.6 %
Optimum Moisture: 10.6 %
Relative compaction: 95
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/14/2022 ✔