Summary for Test 2022-02-01-46-4
Test performed: AASHTO T84-14Project Information
Project Identifiers | Project ID: 214469 DEA: 030H08U4 EFIS: 0319000029 |
---|---|
DIST-CO-RTE-PM | 03-SAC-50-L0.2/R6.1 |
Award Date | 06/30/2020 |
Closeout Date | Not set |
Work Description | Sac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC |
Location Description | FROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE |
QA Service Level | 1 (Verified on 10/23/2019) |
Sample Information
Sample Taken Date | 02/01/2022 | Sample Unique Key | 46 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/04/2022 |
Sample type | Verification | A brief description of the sample | 1/2' Virgin Agg |
The quantity of what the sample constitutes | JMF 3 bags cold feed | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Teichert | Last name of sampler or witnessed by | Personnel |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Construction Woodland | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-34-0045 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Teichert Construction Woodland | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-02-01-46
DIME Test ID: 2022-02-01-46-4
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2022-04-08
Test Results
Input Type: Measured
Tester's full name: Thomas Vang
Date of test: 02/14/2022
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 965 grams
Mass of the pycnometer with water (B): 650.8 grams
Mass of the oven dried sample (before pycnometer) (A): 491.1 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 491.1 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.643
Bulk specific gravity (SSD Basis): 2.691
Apparent specific gravity: 2.776
Absorption: 1.8 %
General comments (publicly viewable) (Max 1000 characters): JMF22-003
Test was verified on 4/8/2022 ✔