Summary for Test 2021-06-01-2-3

Test performed: ASTM C1038-14b

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/01/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/01/2021
Sample typeProficiency A brief description of the sampleCCRL pozzolan
The quantity of what the sample constitutes1 box From where was the sample collectedSource
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM218069 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCCRL Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandCCRL
MillCCRL Pozzolan Type of Cementitious MaterialType II/V Cement

Test Details

DIME Sample ID: 2021-06-01-2
DIME Test ID: 2021-06-01-2-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Test Release Date: 2022-03-21

Test Results


Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 06/17/2021
Specimen A Initial measurement at 24 hours: 0.2627 in
Specimen B Initial measurement at 24 hours: 0.2828 in
Specimen C Initial measurement at 24 hours: 0.2693 in
Specimen D Initial measurement at 24 hours: 0.0097 in
Specimen A Final measurement at 14 days: 0.2527 in
Specimen B Final measurement at 14 days: 0.2731 in
Specimen C Final measurement at 14 days: 0.2599 in
Specimen D Final measurement at 14 days: 0 in
The average length of change of the four specimens: -0.097 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/21/2022