Summary for Test 2022-03-07-12-4

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/07/2022 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/15/2022
Sample typeVerification A brief description of the sample1/2" HMA WMA PG 64-10 with 25% RAP
The quantity of what the sample constitutes6 Bags From where was the sample collectedSupplier
First name of sampler or witnessed byErika Last name of sampler or witnessed byGonzalez
Title of samplerTET Telephone number of sampler
Laboratory sample identification22-JMFPP-0030 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasonton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0010
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-03-07-12
DIME Test ID: 2022-03-07-12-4
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2022-03-17

Test Results


Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 03/16/2022
Grading designation: C
Mass of sample (before test): 5003 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4729 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3854 grams
Percent loss after 100 revolutions: 5 %
Percent loss after 500 revolutions: 23 %
General comments (publicly viewable) (Max 1000 characters): At 100 rev and 500 rev.

Test was verified on 3/17/2022