Owner Lab
- CT HQ - Sacramento Aggregate Testing Laboratory
DIME Sample ID 2022-03-07-12
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/07/2022 |
Sample Unique Key | 12 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 03/15/2022 |
Sample type | Verification |
A brief description of the sample | 1/2" HMA WMA PG 64-10 with 25% RAP |
The quantity of what the sample constitutes | 6 Bags |
From where was the sample collected | Supplier |
First name of sampler or witnessed by | Erika |
Last name of sampler or witnessed by | Gonzalez |
Title of sampler | TET |
Telephone number of sampler | |
Laboratory sample identification | 22-JMFPP-0030 |
Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Pleasonton |
Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | |
Structure unique identifier | |
Structure name | |
---|
Material Information
Material Type | Aggregate |
Source Identification (SMARA or name of Pit) | 91-01-0010 |
The fabricator's/manufacturer's product name for the sample | |
The fabricator/manufacturer designation for the sample | |
The plant number | |
A detailed description of where the material sample was collected | Plant |
Where the material sample would have been placed if not sampled | |
Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | |
Lot number | |
Sublot number | |
Aggregate Mix Number | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2022-03-07-12-1 | AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis) | Jay Horton | CT HQ - Sacramento Aggregate Testing Laboratory | 03/16/2022 | Bang Nguyen | Yes | 03/17/2022 | | |
2022-03-07-12-2 | AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity) | Ryan Kester | CT HQ - Sacramento Aggregate Testing Laboratory | 03/16/2022 | Bang Nguyen | Yes | 03/17/2022 | Bulk specific gravity (SSD) of fine aggregate - Bulk specific gravity of fine aggregate - Bulk specific gravity of fine aggregate - Apparent specific gravity of supplemental fines - Absorption of fine aggregate. | |
2022-03-07-12-3 | AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity) | Ryan Kester | CT HQ - Sacramento Aggregate Testing Laboratory | 03/16/2022 | Bang Nguyen | Yes | 03/17/2022 | Bulk Specific Gravity (Oven Dry) of Coarse Aggregate-Absorption of Coarse Aggregate. | |
2022-03-07-12-4 | AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler) | Ryan Kester | CT HQ - Sacramento Aggregate Testing Laboratory | 03/16/2022 | Bang Nguyen | Yes | 03/17/2022 | At 100 rev and 500 rev. | |
2022-03-07-12-5 | AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent) | Jay Horton | CT HQ - Sacramento Aggregate Testing Laboratory | 03/16/2022 | Bang Nguyen | Yes | 03/18/2022 | | |
2022-03-07-12-6 | AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles) | Ryan Kester | CT HQ - Sacramento Aggregate Testing Laboratory | 03/17/2022 | Bang Nguyen | Yes | 03/18/2022 | Crushed particles, coarse aggregate one fractured face Crushed particles, coarse aggregate two fractured faces Crushed particles, fine aggregate (Passing No. 4 sieve and retained on No. 8 sieve) one fractured face. | |
2022-03-07-12-7 | ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles) | Jay Horton | CT HQ - Sacramento Aggregate Testing Laboratory | 03/17/2022 | Bang Nguyen | Yes | 03/18/2022 | % by mass at 5:1 | |
153808153809153810153811153872153873153874
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
No results found. |
Test File Attachments
DIME Test ID: 2022-03-07-12-1 AASHTO T27-14 (Verified)
DIME Test ID: 2022-03-07-12-2 AASHTO T84-14 (Verified)
DIME Test ID: 2022-03-07-12-3 AASHTO T85-13 (Verified)
DIME Test ID: 2022-03-07-12-4 AASHTO T96-02r10 (Verified)
DIME Test ID: 2022-03-07-12-5 AASHTO T176-08 (Verified)
DIME Test ID: 2022-03-07-12-6 AASHTO T335-09r13 (Verified)
DIME Test ID: 2022-03-07-12-7 ASTM D4791-10 (Verified)