Summary for Test 2022-01-21-14-11

Test performed: ASTM C266-15

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/21/2022 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/21/2022
Sample typeProficiency A brief description of the samplePortland Cement
The quantity of what the sample constitutes1 sample From where was the sample collectedManufacturer
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM228223 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCCRL Portland 223 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandCCRL
MillCCRL Type of Cementitious MaterialType II Cement

Test Details

DIME Sample ID: 2022-01-21-14
DIME Test ID: 2022-01-21-14-11
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C266-15: Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles
Test Release Date: 2022-03-17

Test Results


Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 03/15/2022
Initial time of setting: 210 min
Final time of setting: 330 min
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/17/2022