Summary for Test 2021-12-21-21-3
Test performed: ASTM C39-18Project Information
Project Identifiers | Project ID: 215710 DEA: 051N3504 EFIS: 0520000173 |
---|---|
DIST-CO-RTE-PM | 05-SLO-101-37.8/46.0, 37.0/46.0 |
Award Date | 06/09/2021 |
Closeout Date | 09/06/2022 |
Work Description | Replace concrete pavement with precast concrete panels. |
Location Description | Near Atascadero on US 101 from 0.1 mile south of Route 58/10 separation to Traffic Way. |
QA Service Level | 1 (Verified on 07/06/2021) |
Sample Information
Sample Taken Date | 12/21/2021 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/22/2021 |
Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Robert | Last name of sampler or witnessed by | Lopez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | ProCast Products | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | RRM14062 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | TT | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-12-21-21
DIME Test ID: 2021-12-21-21-3
Testing Lab: Pro-Cast Products, Incorporated - Highland
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2022-02-04
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Mike Reyes
Date of test: 01/18/2022
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Maximum load on cylinder 1: 210820 lb
Maximum load on cylinder 2: 216940 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 0
Correction factor for cylinder 2: 0
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 7570 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/4/2022 ✔