Summary for Test 2021-11-20-3-10
Test performed: CTM TEMP1-16
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
Project Identifiers | Project ID: 214993 DEA: 051F5004 EFIS: 0514000003 |
---|---|
DIST-CO-RTE-PM | 05-SB-101,135-70.6/71.2;0.1 |
Award Date | 11/17/2020 |
Closeout Date | 01/11/2024 |
Work Description | CONSTRUCT CONCRETE BRIDGE, BRIDGE REMOVAL, COLD PLANE, PLACE HMA. |
Location Description | SANTA BARBARA COUNTY AT LOS ALAMOS ON ROUTE 101 FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF ROUTE 101/135 SEPARATION AND ON ROUTE 135 AT ROUTE 101/135 SEPARATION |
QA Service Level | 1 (Verified on 09/03/2020) |
Sample Information
Sample Taken Date | 11/20/2021 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/22/2021 |
Sample type | Quality Control | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | 58 CY | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Stephen | Last name of sampler or witnessed by | Haynes |
Title of sampler | QC Inspector Technician | Telephone number of sampler | 9253317125 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | KIE-CON, INC | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | K7010-705 CPO R2 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 112691 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | 20-138 11/20/21 | |
A detailed description of where the material sample was collected | Concrete sample from wheelbarrow | Where the material sample would have been placed if not sampled | G2 Box Girder |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-11-20-3
DIME Test ID: 2021-11-20-3-10
Testing Lab: Kie-Con, Incorporated - Antioch
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Test Release Date: 2022-01-14
Test Results
Input Type: Calculated
Tester's full name: Stephen Haynes
Date of test: 10/11/2022
Precast Maximum Curing Temperature: 126 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/14/2022 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.