Summary for Test 2021-11-30-16-3

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 214991
DEA: 044G2104
EFIS: 0412000310
DIST-CO-RTE-PM04-NAP-121-0.5/1
Award Date05/19/2021
Closeout DateNot set
Work DescriptionWIDEN ROADWAY WITH HMA & REPLACE CULVERT WITH STRUCTURAL CONC BRIDGE.
Location DescriptionNAPA COUNTY NEAR NAPA FROM 0.2 MILE SOUTH TO 0.3 MILE NORTH OF HUICHICA CREEK BRIDGE
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date11/30/2021 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/20/2021
Sample typeQuality Assurance A brief description of the sampleAnchor Bolt hardware
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler3854470624
Laboratory sample identificationna Linked DIME Sample IDna
The fabricator/manufacturer/facility nameUniversal Industrial Sales Inc Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-229-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)20695950 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationA449
Bolt Length(s)20" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size1.0" Bolt Mfg. Lot Number33490
Rocap Test Requirement(s)na Lubricant Requirements(s)none

Test Details

DIME Sample ID: 2021-11-30-16
DIME Test ID: 2021-11-30-16-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-12-10

Test Results


Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 12/09/2021
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 20695950
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A449 01AE
Size: 1 in
Bolt Length: 20 in
Measurement Average: 2.66 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/10/2021