Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-11-30-16

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214991
DEA: 044G2104
EFIS: 0412000310
DIST-CO-RTE-PM04-NAP-121-0.5/1
Award Date05/19/2021
Closeout DateNot set
Work DescriptionWIDEN ROADWAY WITH HMA & REPLACE CULVERT WITH STRUCTURAL CONC BRIDGE.
Location DescriptionNAPA COUNTY NEAR NAPA FROM 0.2 MILE SOUTH TO 0.3 MILE NORTH OF HUICHICA CREEK BRIDGE
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date11/30/2021 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/20/2021
Sample typeQuality Assurance A brief description of the sampleAnchor Bolt hardware
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler3854470624
Laboratory sample identificationna Linked DIME Sample IDna
The fabricator/manufacturer/facility nameUniversal Industrial Sales Inc Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-229-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)20695950 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationA449
Bolt Length(s)20" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size1.0" Bolt Mfg. Lot Number33490
Rocap Test Requirement(s)na Lubricant Requirements(s)none

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-11-30-16-1ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory12/09/2021bewing
Yes
12/10/2021A449 Bolt
2021-11-30-16-2ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory12/09/2021Brian Ewing
Yes
12/10/2021
2021-11-30-16-3ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory12/09/2021Brian Ewing
Yes
12/10/2021

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-11-30-16-1 ASTM F606-14 (Verified)
DIME Test ID: 2021-11-30-16-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-11-30-16-3 ASTM B499-14 (Verified)