Summary for Test 2016-02-08-3-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 209217 DEA: 080F5404 EFIS: 0800000136 COOP: 081468 |
---|---|
DIST-CO-RTE-PM | 08-RIV-91,15-0.0/13.04, 35.64/45.14 |
Award Date | 09/09/2013 |
Closeout Date | 09/20/2023 |
Work Description | SR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas. |
Location Description | 08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14 |
QA Service Level | 1 (Verified on 08/07/2014) |
Sample Information
Sample Taken Date | 02/08/2016 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/12/2016 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | A | Last name of sampler or witnessed by | Nguyen |
Title of sampler | TETQ | Telephone number of sampler | Unknown |
Laboratory sample identification | 888-SRL143 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Holliday Rock Chino | Transportation Laboratory (TL) Number | SRL 143 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | CM5636 |
---|---|---|---|
The truck number from where the sample was collected | 213 | The batch plant ticket number from where the sample was collected | 118041207 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Plant |
A detailed description of where the material sample was collected | BAck of the concrete truck | Where the material sample would have been placed if not sampled | BR 18 RT DECK |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-02-08-3
DIME Test ID: 2016-02-08-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-02-22
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 02/22/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.96 in
Average diameter of cylinder 2: 5.97 in
Maximum load on cylinder 1: 137480 lb
Maximum load on cylinder 2: 128720 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 14 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 27.9 in^2
Cross sectional area of cylinder 2: 27.99 in^2
Compressive strength of cylinder 1: 4927.6 psi
Compressive strength of cylinder 2: 4598.8 psi
Compressive strength (to nearest 10 psi): 4760 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/22/2016 ✔