Summary for Test 2021-10-07-83-5
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 993331 DEA: 023H6904 EFIS: 0218000010 |
---|---|
DIST-CO-RTE-PM | 02-PLU-89-30/R42.1 |
Award Date | 11/21/2024 |
Closeout Date | Not set |
Work Description | ALMANOR WEST REHAB - ROADWAY REHABILITATION |
Location Description | IN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36. |
QA Service Level | 1 (Verified on 10/14/2021) |
Sample Information
Sample Taken Date | 10/07/2021 | Sample Unique Key | 83 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/07/2021 |
Sample type | Preliminary | A brief description of the sample | Soil |
The quantity of what the sample constitutes | 2 bags for structural section recommendation | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Dan | Last name of sampler or witnessed by | Curran |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | D78952 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 897766 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-PLU-89-41.0-45ft RT of CL | |
Where the material sample would have been placed if not sampled | 02 PLU 89 |
Test Details
DIME Sample ID: 2021-10-07-83
DIME Test ID: 2021-10-07-83-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2021-11-16
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 10/28/2021
Minimum soil resistance of the lab measurement: 10600 Ohms
Soil sample temperature: 20.4 C
Soil box constant: 1
pH of soil: 5.92
Minimum soil resistance corrected to 15.5: 11898.5 Ohm-cm
Minimum soil resistivity at 15.5: 11899 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/16/2021 ✔