Summary for Test 2021-09-09-43-4
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
---|---|
DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
Award Date | 12/03/2019 |
Closeout Date | 09/28/2022 |
Work Description | San Mateo US 101 Express Lanes North |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 09/09/2021 | Sample Unique Key | 43 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/14/2021 |
Sample type | Verification | A brief description of the sample | 16 Mohes of RHMA-G |
The quantity of what the sample constitutes | 16 Boxes | From where was the sample collected | Source |
First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Cruz |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Hanson Sunol | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-09-43
DIME Test ID: 2021-09-09-43-4
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-10-14
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Randy Cortez
Date of test: 09/30/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: 0.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 0.0 g
Mass of HMA Sample prior to ignition: 1,616.1 g
Mass Loss: 0.0 g
Mass of aggregate remaining after ignition: 1,476.9 g
Correction Factor (Percent by mass of HMA Specimen): 1.04 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 7.57 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/14/2021 ✔