Summary for Test 2021-09-09-42-2
Test performed: AASHTO T84-14Project Information
Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
---|---|
DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
Award Date | 12/03/2019 |
Closeout Date | 09/28/2022 |
Work Description | San Mateo US 101 Express Lanes North |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 09/09/2021 | Sample Unique Key | 42 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/14/2021 |
Sample type | Verification | A brief description of the sample | 4 Bags of Aggregates |
The quantity of what the sample constitutes | 4 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Cruz |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Hanson Sunol | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA or name of Pit) | 91-01-0011 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Hanson Sunol Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-09-42
DIME Test ID: 2021-09-09-42-2
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-10-14
Test Results
Input Type: Measured
Tester's full name: Nicholas Shelly
Date of test: 09/23/2021
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 963.6 grams
Mass of the pycnometer with water (B): 653.2 grams
Mass of the oven dried sample (before pycnometer) (A): 489.2 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 489.2 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.580
Bulk specific gravity (SSD Basis): 2.637
Apparent specific gravity: 2.736
Absorption: 2.2 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/14/2021 ✔