Summary for Test 2021-07-16-19-3

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214402
DEA: 010E7704
EFIS: 0115000009
DIST-CO-RTE-PM01-HUM-101-R17.9/87.8
Award Date01/21/2020
Closeout Date07/21/2023
Work DescriptionSTRENGTHEN 2 BRIDGES.
Location DescriptionHUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD
QA Service Level1 (Verified on 09/16/2019)

Sample Information

Sample Taken Date07/16/2021 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/21/2021
Sample typeQuality Assurance A brief description of the sample1" and 5/8" A325 HDG fastener assemblies
The quantity of what the sample constitutes734 assemblies total From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerAssociate Steel Inspector Telephone number of sampler510-376-7155
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCK Johnson Industries Transportation Laboratory (TL) NumberC8356670
Inspector Lot Number from the Transportation Laboratory (TL) FormB9-015-21 Structure unique identifier
Structure namevarious

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)445378AR
Heat Number(s)Bolt 100105212 Nut 80000006661 Washer 209198 Nut Mfg. Lot Number(s)452164A
Washer Mfg. Lot Number(s)D9684 Bolt SpecificationA325 Hvy Hex HDG
Bolt Length(s)5 1/2" Nut SpecificationF563 DH HDG
Washer SpecificationF436 HDG FinishHot Dip Galvanized
Diameter/Size1" dia Bolt Mfg. Lot Number445378A
Rocap Test Requirement(s)yes Lubricant Requirements(s)yes

Test Details

DIME Sample ID: 2021-07-16-19
DIME Test ID: 2021-07-16-19-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2021-07-22

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/21/2021
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11445378A1.000087131387.5810.00A325fsaylor

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Bluehill Data Point File

Test was verified on 7/22/2021