Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2021-07-16-19
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214402 DEA: 010E7704 EFIS: 0115000009 |
---|---|
DIST-CO-RTE-PM | 01-HUM-101-R17.9/87.8 |
Award Date | 01/21/2020 |
Closeout Date | 07/21/2023 |
Work Description | STRENGTHEN 2 BRIDGES. |
Location Description | HUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD |
QA Service Level | 1 (Verified on 09/16/2019) |
Sample Information
Sample Taken Date | 07/16/2021 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1" and 5/8" A325 HDG fastener assemblies |
The quantity of what the sample constitutes | 734 assemblies total | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CK Johnson Industries | Transportation Laboratory (TL) Number | C8356670 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-015-21 | Structure unique identifier | |
Structure name | various |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 445378AR |
---|---|---|---|
Heat Number(s) | Bolt 100105212 Nut 80000006661 Washer 209198 | Nut Mfg. Lot Number(s) | 452164A |
Washer Mfg. Lot Number(s) | D9684 | Bolt Specification | A325 Hvy Hex HDG |
Bolt Length(s) | 5 1/2" | Nut Specification | F563 DH HDG |
Washer Specification | F436 HDG | Finish | Hot Dip Galvanized |
Diameter/Size | 1" dia | Bolt Mfg. Lot Number | 445378A |
Rocap Test Requirement(s) | yes | Lubricant Requirements(s) | yes |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2021-07-16-19-1 ASTM F606-14a (Verified)
DIME Test ID: 2021-07-16-19-2 ASTM F606-14a (Verified)
DIME Test ID: 2021-07-16-19-3 ASTM F606-14a (Verified)
DIME Test ID: 2021-07-16-19-4 ASTM F606-14a (Verified)
DIME Test ID: 2021-07-16-19-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-16-19-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-16-19-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-16-19-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-16-19-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-16-19-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-16-19-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-16-19-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-16-19-13 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-16-19-14 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-07-16-19-15 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-16 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-17 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-18 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-19 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-20 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-21 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-22 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-23 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-24 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-25 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-26 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-27 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-28 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-29 ASTM B499-14 (Verified)
DIME Test ID: 2021-07-16-19-30 ASTM E18-15 (Verified)
DIME Test ID: 2021-07-16-19-31 ASTM E18-15 (Verified)
DIME Test ID: 2021-07-16-19-32 ASTM E18-15 (Verified)