Summary for Test 2021-04-27-28-5
Test performed: AASHTO T304-11Project Information
Project Identifiers | Project ID: 214511 DEA: 010E0004 EFIS: 0113000091 |
---|---|
DIST-CO-RTE-PM | 01-HUM-101-84.4/84.8 |
Award Date | 01/29/2020 |
Closeout Date | 11/22/2023 |
Work Description | BRIDGE RAIL REPLACEMENT. |
Location Description | HUMBOLDT COUNTY NEAR ARCATA FROM JACOBY CREEK BRIDGE TO GANNON SLOUGH BRIDGE |
QA Service Level | 1 (Verified on 11/13/2019) |
Sample Information
Sample Taken Date | 04/27/2021 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/25/2021 |
Sample type | Dispute Resolution | A brief description of the sample | 1/2" HMA NO RAP |
The quantity of what the sample constitutes | _ | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | _ | Last name of sampler or witnessed by | _ |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 21-JMF-0102 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Mercer Fraser - Fortuna | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-12-0002 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-04-27-28
DIME Test ID: 2021-04-27-28-5
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-06-07
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 06/04/2021
Mass of measure: 187.8 grams
Bulk dry specific gravity: 2.568
Mass of sample and measure #1: 330.9 grams
Mass of sample and measure #2: 331.1 grams
Volume of cylinder: 100.0 mL
Mass of sample #1: 143.1 grams
Mass of sample #2: 143.3 grams
Uncompacted voids #1: 44.3 %
Uncompacted voids #2: 44.2 %
Average uncompacted voids: 44.3 %
General comments (publicly viewable) (Max 1000 characters): Method A
Test was verified on 6/7/2021 ✔