Summary for Test 2021-04-27-28-8
Test performed: AASHTO T84-14Project Information
Project Identifiers | Project ID: 214511 DEA: 010E0004 EFIS: 0113000091 |
---|---|
DIST-CO-RTE-PM | 01-HUM-101-84.4/84.8 |
Award Date | 01/29/2020 |
Closeout Date | 11/22/2023 |
Work Description | BRIDGE RAIL REPLACEMENT. |
Location Description | HUMBOLDT COUNTY NEAR ARCATA FROM JACOBY CREEK BRIDGE TO GANNON SLOUGH BRIDGE |
QA Service Level | 1 (Verified on 11/13/2019) |
Sample Information
Sample Taken Date | 04/27/2021 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/25/2021 |
Sample type | Dispute Resolution | A brief description of the sample | 1/2" HMA NO RAP |
The quantity of what the sample constitutes | _ | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | _ | Last name of sampler or witnessed by | _ |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 21-JMF-0102 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Mercer Fraser - Fortuna | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-12-0002 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-04-27-28
DIME Test ID: 2021-04-27-28-8
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-06-07
Test Results
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 06/02/2021
Mass of saturated surface dry sample (before pycnometer) (S): 500.6 grams
Mass of the pycnometer with water and aggregate (C): 987.2 grams
Mass of the pycnometer with water (B): 677.9 grams
Mass of the oven dried sample (before pycnometer) (A): 491.2 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.6 grams
Mass of the oven dry aggregate (for absorption) (A): 491.2 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.568
Bulk specific gravity (SSD Basis): 2.617
Apparent specific gravity: 2.700
Absorption: 1.9 %
General comments (publicly viewable) (Max 1000 characters): - Bulk specific gravity (SSD) of fine aggregate
- Bulk specific gravity of fine aggregate
- Bulk specific gravity of fine aggregate
- Apparent specific gravity of supplemental fines
- Absorption of fine aggregate
Test was verified on 6/7/2021 ✔