Summary for Test 2021-05-13-8-6

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 214355
DEA: 120K0214
EFIS: 1214000096
DIST-CO-RTE-PM12-ORA-5-12.4/14.5
Award Date12/20/2019
Closeout DateNot set
Work DescriptionSouth County Improvement Project (Phase 1 - Avery/Crown Valley) PLACE HMA, INSTALL CONC PAVEMENT, RETAIN WALL, MODIFY ELECT SYS. | Add one lane btwn 73 & Oso PKWY
Location DescriptionORANGE COUNTY IN SAN JUAN CAPISTRANO, LAGUNA HILLS, LAGUNA NIGUEL AND MISSION VIEJO FROM 0.5 MILE SOUTH OF AVERY PARKWAY UNDERCROSSING TO 0.8 MILE NORTH OF CROWN VALLEY PARKWAY OVERCROSSING
QA Service Level1 (Verified on 10/31/2019)

Sample Information

Sample Taken Date05/13/2021 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2021
Sample typeQuality Assurance A brief description of the samplenVent LENTON TERMINATOR (D14) with LENTON PLUS cold worked taper threaded rebar
The quantity of what the sample constitutes(8) nVent LENTON TERMINATOR (D14) with LENTON PLUS cold worked taper threaded rebar From where was the sample collectedManufacturer
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byMarin
Title of samplerAMR Telephone number of sampler951-500-0685
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCoreslab Structures L A Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL133-059-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4102817 Head Manufacturer Lot Number(s)L9805 L9766
Rebar Size#8 Headed Bar Model Name9TT 17 02
Size of HeadFull Size - 9x Head Connection TypeTaper Threaded
Head ShapeCircular Rebar ManufacturerCMC Steel Arizona
Head ManufacturerERICO International Corporation nVent Head FabricatornVent Lenton
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2021-05-13-8
DIME Test ID: 2021-05-13-8-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-05-18

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/14/2021
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
120.7979375100475Head Pull Offfsaylor

General comments (publicly viewable) (Max 1000 characters): Head Pull Off
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 5/18/2021