Summary for Test 2021-05-13-8-2
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 214355 DEA: 120K0214 EFIS: 1214000096 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-12.4/14.5 |
Award Date | 12/20/2019 |
Closeout Date | Not set |
Work Description | South County Improvement Project (Phase 1 - Avery/Crown Valley) PLACE HMA, INSTALL CONC PAVEMENT, RETAIN WALL, MODIFY ELECT SYS. | Add one lane btwn 73 & Oso PKWY |
Location Description | ORANGE COUNTY IN SAN JUAN CAPISTRANO, LAGUNA HILLS, LAGUNA NIGUEL AND MISSION VIEJO FROM 0.5 MILE SOUTH OF AVERY PARKWAY UNDERCROSSING TO 0.8 MILE NORTH OF CROWN VALLEY PARKWAY OVERCROSSING |
QA Service Level | 1 (Verified on 10/31/2019) |
Sample Information
Sample Taken Date | 05/13/2021 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2021 |
Sample type | Quality Assurance | A brief description of the sample | nVent LENTON TERMINATOR (D14) with LENTON PLUS cold worked taper threaded rebar |
The quantity of what the sample constitutes | (8) nVent LENTON TERMINATOR (D14) with LENTON PLUS cold worked taper threaded rebar | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Rigoberto | Last name of sampler or witnessed by | Marin |
Title of sampler | AMR | Telephone number of sampler | 951-500-0685 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Coreslab Structures L A Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L133-059-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 4102817 | Head Manufacturer Lot Number(s) | L9805 L9766 |
Rebar Size | #8 | Headed Bar Model Name | 9TT 17 02 |
Size of Head | Full Size - 9x | Head Connection Type | Taper Threaded |
Head Shape | Circular | Rebar Manufacturer | CMC Steel Arizona |
Head Manufacturer | ERICO International Corporation nVent | Head Fabricator | nVent Lenton |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2021-05-13-8
DIME Test ID: 2021-05-13-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-05-18
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/14/2021
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 0.79 | 80379 | 101746 | Head Pull Off | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Head Pull Off
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 5/18/2021 ✔