Summary for Test 2021-03-05-20-5
Test performed: ASTM D4791-10Project Information
Project Identifiers | Project ID: 214492 DEA: 033F5404 EFIS: 0313000136 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99,160-4.5/5.7,R44.5 |
Award Date | 01/24/2020 |
Closeout Date | 07/28/2022 |
Work Description | FURNISH PRECAST PRESTRESSED CONCRETE SLAB & PLACE STRUCTURAL CONCRETE. |
Location Description | SACRAMENTO COUNTY NEAR GALT ON ROUTE 99 FROM NORTH OF MINGO ROAD TO SOUTH OF ARNO ROAD OVERCROSSING AND IN SACRAMENTO ON ROUTE 160 AT AMERICAN RIVER BRIDGE |
QA Service Level | 1 (Verified on 10/23/2019) |
Sample Information
Sample Taken Date | 03/05/2021 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/08/2021 |
Sample type | Verification | A brief description of the sample | 3/4" (Nominal) Untreated Virgin Aggregate |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Sam Mossallem (Witness) | Last name of sampler or witnessed by | Teichert Personnel (SAMPLER) |
Title of sampler | Teichert Personnel | Telephone number of sampler | Unknown |
Laboratory sample identification | JMF21-009 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Teichert Perkins - Continuous Plant Dreyer Drum | Transportation Laboratory (TL) Number | C 849135 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-34-0045::ASPEN IV SOUTH |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Cold Feed |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Lot number | Unknown | |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-03-05-20
DIME Test ID: 2021-03-05-20-5
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2021-04-19
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Thomas Stinnett
Date of test: 03/16/2021
Weighted percentage of particles (by mass) that were flat and elongated: 1 %
Weighted percentage of particles (by mass) that were not flat and elongated: 99 %
General comments (publicly viewable) (Max 1000 characters): JMF21-009.
Test was verified on 4/19/2021 ✔