Summary for Test 2021-03-30-11-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196 |
---|---|
DIST-CO-RTE-PM | 08-RIV-10-6.7/R25.1 |
Award Date | 11/26/2019 |
Closeout Date | 11/01/2023 |
Work Description | Remove concrete pavement and base, and place HMA and JPCP |
Location Description | ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON. |
QA Service Level | 1 (Verified on 01/09/2020) |
Sample Information
Sample Taken Date | 03/30/2021 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/31/2021 |
Sample type | Quality Control | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | O |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 1012-18 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | COFFMAN | Transportation Laboratory (TL) Number | SET 18 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 1906-23 |
---|---|---|---|
The truck number from where the sample was collected | na | The batch plant ticket number from where the sample was collected | 18 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | JOB | Where the material sample would have been placed if not sampled | I10 WB LINE H LANE 4 AND SHOULDER STA 55780 |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-03-30-11
DIME Test ID: 2021-03-30-11-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-04-06
Test Results
Unit system used?: US Units
Number of specimens: 6
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 04/06/2021
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.97 in
Average diameter of cylinder 3: 5.97 in
Average diameter of cylinder 4: 5.97 in
Average diameter of cylinder 5: 5.98 in
Average diameter of cylinder 6: 5.97 in
Maximum load on cylinder 1: 21425 lb
Maximum load on cylinder 2: 21880 lb
Maximum load on cylinder 3: 21945 lb
Maximum load on cylinder 4: 21820 lb
Maximum load on cylinder 5: 21995 lb
Maximum load on cylinder 6: 21190 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Type of fracture pattern of cylinder 4: 2
Type of fracture pattern of cylinder 5: 2
Type of fracture pattern of cylinder 6: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Correction factor for cylinder 4: 1.00
Correction factor for cylinder 5: 1.00
Correction factor for cylinder 6: 1.00
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 27.99 in^2
Cross sectional area of cylinder 3: 27.99 in^2
Cross sectional area of cylinder 4: 27.99 in^2
Cross sectional area of cylinder 5: 28.09 in^2
Cross sectional area of cylinder 6: 27.99 in^2
Compressive strength of cylinder 1: 765.5 psi
Compressive strength of cylinder 2: 781.7 psi
Compressive strength of cylinder 3: 784.0 psi
Compressive strength of cylinder 4: 779.6 psi
Compressive strength of cylinder 5: 783.0 psi
Compressive strength of cylinder 6: 757.1 psi
Compressive strength (to nearest 10 psi): 780 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/6/2021 ✔