Summary for Test 2021-01-28-16-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
Award Date | 04/21/2020 |
Closeout Date | Not set |
Work Description | Panther Creek & Hunter Creek Bridges |
Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
Sample Taken Date | 01/28/2021 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/08/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1-1/4” x 3-1/2” bolt with washer and nut |
The quantity of what the sample constitutes | 1180 assemblies | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Rex | Last name of sampler or witnessed by | Harrison |
Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 904-238-8258 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Acrow Bridge | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Temporary Modular Bridge |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | AB584 |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | ||
Washer Mfg. Lot Number(s) | Bolt Specification | ASTM F3125 Grade A325 | |
Bolt Length(s) | 3-1/2" | Nut Specification | ASTM A563 Grade DH |
Washer Specification | ASTM F436 | Finish | HDG ASTM A153 |
Diameter/Size | 1-1/4" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2021-01-28-16
DIME Test ID: 2021-01-28-16-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-02-16
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 02/11/2021
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1 | AB584 N | 150214 | Nut Proof | bewing |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 2/16/2021 ✔