Summary for Test 2021-01-28-16-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214579
DEA: 010B0904
EFIS: 0100020444
DIST-CO-RTE-PM01-DN-101-8.2/8.7
Award Date04/21/2020
Closeout DateNot set
Work DescriptionPanther Creek & Hunter Creek Bridges
Location DescriptionDEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
QA Service Level1 (Verified on 03/02/2020)

Sample Information

Sample Taken Date01/28/2021 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/08/2021
Sample typeQuality Assurance A brief description of the sample1-1/4” x 3-1/2” bolt with washer and nut
The quantity of what the sample constitutes1180 assemblies From where was the sample collectedFabricator
First name of sampler or witnessed byRex Last name of sampler or witnessed byHarrison
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler904-238-8258
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAcrow Bridge Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameTemporary Modular Bridge

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)AB584
Heat Number(s) Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationASTM F3125 Grade A325
Bolt Length(s)3-1/2" Nut SpecificationASTM A563 Grade DH
Washer SpecificationASTM F436 FinishHDG ASTM A153
Diameter/Size1-1/4" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2021-01-28-16
DIME Test ID: 2021-01-28-16-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-02-16

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 02/11/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11AB584 N150214Nut Proofbewing

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 2/16/2021