Summary for Test 2021-01-12-1-3
Test performed: ASME B1.2-83r01Project Information
Project Identifiers | Project ID: 214029 DEA: 07301104 EFIS: 0714000009 |
---|---|
DIST-CO-RTE-PM | 07-LA-60,710-710-R2.8/11.8, 24.1/25.1 |
Award Date | 06/03/2019 |
Closeout Date | 10/17/2023 |
Work Description | Roadway ex, place jointed plain concrete pavement & concrete barrieres |
Location Description | In Los Angeles County at avocado Heights on Route 60 from 0.5 Mile west of Route 60/710 Separation to Route 60/605 Separation AND on Route 710 from 0.5 miles south of Route 710/60 Separation to 0.5 mile north of Route 710/60 Separation. |
QA Service Level | 1 (Verified on 06/25/2019) |
Sample Information
Sample Taken Date | 01/12/2021 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/14/2021 |
Sample type | Quality Assurance | A brief description of the sample | Anchor Bolts 2 1/2" |
The quantity of what the sample constitutes | 960 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Lund |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 1-385-447-0624 |
Laboratory sample identification | NA | Linked DIME Sample ID | NA |
The fabricator/manufacturer/facility name | Universal Industrial Sales Inc | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B390-004-21 | Structure unique identifier | |
Structure name | NA |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA |
---|---|---|---|
Heat Number(s) | 1202024451 | Nut Mfg. Lot Number(s) | NA |
Washer Mfg. Lot Number(s) | NA | Bolt Specification | F1554-55 |
Bolt Length(s) | 5'-0" | Nut Specification | NA |
Washer Specification | NA | Finish | HDG |
Diameter/Size | 2.5" | Bolt Mfg. Lot Number | NA |
Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | NA |
Test Details
DIME Sample ID: 2021-01-12-1
DIME Test ID: 2021-01-12-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Test Release Date: 2021-01-25
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 01/21/2021
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 1202024451
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: YELLOW
Size: 2.5 in
Bolt Length: 60 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/25/2021 ✔