Test 2020-06-18-47-4 (AASHTO T304-11) Summary

Project Information
Project IdentifiersProject ID: 214797
DEA: 031G2504
EFIS: 0318000107
DIST-CO-RTE-PM03-ED-193-19.3/R24.7
Work DescriptionCOLD PLANE AC PAVEMENT, RHMA-G OVERLAY, & REPLACE GUARDRAIL.
Location DescriptionEL DORADO COUNTY NEAR PLACERVILLE FROM 0.1 MILE NORTH OF GARDEN VALLEY ROAD TO SOUTH FORK AMERICAN RIVER BRIDGE
Sample Information
Sample Taken Date6/18/2020 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/19/2020
Sample typeVerification A brief description of the sample1/2 inch RHMA-G
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byGRI Personnel Last name of sampler or witnessed byGRI Personnel
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameGeorge Reed - Clements Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-03-0020
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBatch Plant Hot Bins
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID JMF3512-2020-300-2020-GR-003R-VSS, JMF3513-2020-214
Test Details
DIME Sample ID: 2020-06-18-47
DIME Test ID: 2020-06-18-47-4
Testing Lab: CT D03 - North Region Materials Lab
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2020-11-06
Test Results

What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 07/21/2020
Bulk dry specific gravity: 2.745
Average uncompacted voids:46.7 %
General comments (publicly viewable) (Max 1000 characters): JMF20-012B

Test was verified on 11/06/2020