Test 2020-10-08-9-1 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 214175
DEA: 030H4804
EFIS: 0315000198
DIST-CO-RTE-PM03-SAC-99-0.1/1.6,11.8/21.6
Work DescriptionCOLD PLANE AC PAVEMENT AND RHMA OVERLAY.
Location DescriptionSACRAMENTO COUNTY IN AND NEAR GALT FROM DRY CREEK BRIDGE TO SIMMERHORN ROAD AND IN ELK GROVE AND SACRAMENTO FROM 0.9 MILE SOUTH OF ELK GROVE BOULEVARD TO MARTIN LUTHER KING JR BOULEVARD
Sample Information
Sample Taken Date10/8/2020 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/20/2020
Sample typeQuality Assurance A brief description of the sample1 1/4-7 X 3 3/4 A325
The quantity of what the sample constitutes46 From where was the sample collectedFabricator
First name of sampler or witnessed byRoland Last name of sampler or witnessed byMaynard
Title of samplerQA Laboratory sample identification
The fabricator/manufacturer/facility nameStructural and Steel Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS64-010-20 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)09620C
Heat Number(s)100093998 Nut Mfg. Lot Number(s)369545A
Washer Mfg. Lot Number(s)D7043 Bolt SpecificationA325
Bolt Length(s)3 3/4" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1.25" Bolt Mfg. Lot Number416756A
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2020-10-08-9
DIME Test ID: 2020-10-08-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-10-27
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/22/2020
UTM:450kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A369545A150329Proof Loadfsaylor

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/27/2020