Test 2020-08-06-44-4 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 213603
DEA: 07301504
EFIS: 0714000020
DIST-CO-RTE-PM07-LA-1,10-R34.6/35.2,R2.1/18.4
Work DescriptionREPLACING CONCRETE AND AC PAVEMENT
Location DescriptionLOS ANGELES COUNTY IN SANTA MONICA AND LOS ANGELES ON ROUTE 1 FROM 0.1 MILE WEST OF MAIN STREET OVERCROSSING TO ROUTE 1/10 SEPARATION AND ON ROUTE 10 FROM ROUTE 1/10 SEPARATION TO ROUTE 5/10 SEPARATION AND AT ROUTE 10/110 SEPARATION
Sample Information
Sample Taken Date8/6/2020 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/20/2020
Sample typeVerification A brief description of the sampleJMF 1/2" HMA-A-SP r15 0.5% LAS
The quantity of what the sample constitutes3 Bags Of Coldfeed Agg., 2 Bags Of rap From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Materials Irwindale Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0514A-20
The fabricator/manufacturer/facility nameVulcan Materials-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number320819A IRW LTR A detailed description of where the material sample was collectedBelt Cut at Vulcan Materials-Irwindale
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2020-08-06-44
DIME Test ID: 2020-08-06-44-4
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-08-31
Test Results

Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 08/26/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 988.2 grams
Mass of the pycnometer with water (B): 674.7 grams
Mass of the oven dried sample (before pycnometer) (A): 489.7 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 489.7 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.626
Bulk specific gravity (SSD Basis):2.681
Apparent specific gravity:2.779
Absorption:2.1 %
General comments (publicly viewable) (Max 1000 characters):