Test 2020-07-10-7-4 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
Sample Information
Sample Taken Date7/10/2020 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/14/2020
Sample typeVerification A brief description of the sampleJMF 3/4" HMA-A-SP R15 0.50% LAS
The quantity of what the sample constitutes4 Bags Coldfeed Aggregate, 2 bags Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Irwindale Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0432A-20
The fabricator/manufacturer/facility nameVulcan Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number224112A IRW SJR A detailed description of where the material sample was collectedBelt Cut at Vulcan Irwindale Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2020-07-10-7
DIME Test ID: 2020-07-10-7-4
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-07-27
Test Results

Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 07/21/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 966.9 grams
Mass of the pycnometer with water (B): 654.3 grams
Mass of the oven dried sample (before pycnometer) (A): 489.1 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 489.1 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.610
Bulk specific gravity (SSD Basis):2.668
Apparent specific gravity:2.771
Absorption:2.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/27/2020