Summary for Test 2020-07-08-1-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 213970 DEA: 080K1214 EFIS: 0815000245 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-12.5/14.8 |
Award Date | 12/23/2019 |
Closeout Date | 01/18/2022 |
Work Description | REPLACE PCC PAVEMENT WITH JPCP AND PRECAST JOINTED CONCRETE PAVEMENT. |
Location Description | SAN BERNARDINO COUNTY IN FONTANA AND NEAR DEVORE FROM 0.3 MILE SOUTH OF SIERRA AVENUE UNDERCROSSING TO GLEN HELEN PARKWAY UNDERCROSSING |
QA Service Level | 1 (Verified on 12/12/2019) |
Sample Information
Sample Taken Date | 07/08/2020 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/13/2020 |
Sample type | Quality Assurance | A brief description of the sample | 3/4"-10 all thread rod with nut and plate washer |
The quantity of what the sample constitutes | 130 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 6466327821 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cordova Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | 134-142-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | All Thread 10624770 Nuts DL19102901 Plate washers 1202011437 | Nut Mfg. Lot Number(s) | 431189A |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | ASTM A449 type 1 |
Bolt Length(s) | approx. 48" | Nut Specification | A563-15 |
Washer Specification | ASTM A36/A529 Gr 50/44W/50W | Finish | HDG |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-07-08-1
DIME Test ID: 2020-07-08-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2020-07-22
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/21/2020
UTM: 400kip
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | UNC 3/4 | 0.334 | 44336 | 197 | 132742 | 121858 | 40701 | A449 All threaded Rod |
General comments (publicly viewable) (Max 1000 characters): A449 All threaded Rod
Test Graph
Source: Bluehill Data Point FileTest was verified on 7/22/2020 ✔