Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2020-07-08-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213970
DEA: 080K1214
EFIS: 0815000245
DIST-CO-RTE-PM08-SBD-15-12.5/14.8
Award Date12/23/2019
Closeout Date01/18/2022
Work DescriptionREPLACE PCC PAVEMENT WITH JPCP AND PRECAST JOINTED CONCRETE PAVEMENT.
Location DescriptionSAN BERNARDINO COUNTY IN FONTANA AND NEAR DEVORE FROM 0.3 MILE SOUTH OF SIERRA AVENUE UNDERCROSSING TO GLEN HELEN PARKWAY UNDERCROSSING
QA Service Level1 (Verified on 12/12/2019)

Sample Information

Sample Taken Date07/08/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/13/2020
Sample typeQuality Assurance A brief description of the sample3/4"-10 all thread rod with nut and plate washer
The quantity of what the sample constitutes130 From where was the sample collectedJob Site
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Telephone number of sampler6466327821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCordova Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form134-142-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)All Thread 10624770 Nuts DL19102901 Plate washers 1202011437 Nut Mfg. Lot Number(s)431189A
Washer Mfg. Lot Number(s)N/A Bolt SpecificationASTM A449 type 1
Bolt Length(s)approx. 48" Nut SpecificationA563-15
Washer SpecificationASTM A36/A529 Gr 50/44W/50W FinishHDG
Diameter/Size3/4" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-07-08-1-1ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/21/2020fsaylor
Yes
07/22/2020A449 All threaded Rod
2020-07-08-1-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/21/2020fsaylor
Yes
07/22/2020Nut Proof
2020-07-08-1-3ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/21/2020Fred Saylor
Yes
07/22/2020
2020-07-08-1-4ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/21/2020Fred Saylor
Yes
07/22/2020
2020-07-08-1-5ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/21/2020Fred Saylor
Yes
07/22/2020
2020-07-08-1-6ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/21/2020Fred Saylor
Yes
07/22/2020
2020-07-08-1-7ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/21/2020Fred Saylor
Yes
07/22/2020
2020-07-08-1-8ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/21/2020Fred Saylor
Yes
07/22/2020
2020-07-08-1-9ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/21/2020Fred Saylor
Yes
07/22/2020
2020-07-08-1-10ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/21/2020Fred Saylor
Yes
07/22/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-07-08-1-1 ASTM F606-14 (Verified)
DIME Test ID: 2020-07-08-1-2 ASTM F606-14a (Verified)
DIME Test ID: 2020-07-08-1-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-07-08-1-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-07-08-1-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-07-08-1-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-07-08-1-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-07-08-1-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-07-08-1-9 ASTM B499-14 (Verified)
DIME Test ID: 2020-07-08-1-10 ASTM B499-14 (Verified)
DIME Test ID: 2020-07-08-1-11 ASTM B499-14 (Verified)
DIME Test ID: 2020-07-08-1-12 ASTM B499-14 (Verified)
DIME Test ID: 2020-07-08-1-13 ASTM B499-14 (Verified)
DIME Test ID: 2020-07-08-1-14 ASTM B499-14 (Verified)