Test 2019-09-24-2-3 (ASTM F606-14a) Summary

Project Information
Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
Sample Information
Sample Taken Date9/24/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing9/26/2019
Sample typeQuality Assurance A brief description of the sample3/4"-10 ASTM A563-DH Galvanized Heavy Hex Nut
The quantity of what the sample constitutes7 of 26,334 From where was the sample collectedDistributor
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameUnytite Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-002-19 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)n/a
Heat Number(s)190423 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s)n/a Bolt Specificationn/a
Bolt Length(s) Nut SpecificationASTM A563-DH
Washer Specificationn/a Finish
Diameter/Size3/4" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2019-09-24-2
DIME Test ID: 2019-09-24-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-10-15
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/10/2019
UTM:450kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11C31183-19042350790Nut Proof Loadspaine

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/15/2019