Test 2019-04-17-54-5 (AASHTO T176-08) Summary

Project Information
Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date4/17/2019 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/18/2019
Sample typeVerification A brief description of the sample3/4" HMA - A
The quantity of what the sample constitutes1 From where was the sample collectedSource
First name of sampler or witnessed byIggy Last name of sampler or witnessed byHerrera
Title of sampler Laboratory sample identification19-JMF-0118 replace with 19-JMF-0129
The fabricator/manufacturer/facility nameGranite Construction Company Vernalis Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-39-0002::VERNALIS
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID JMF3513-2019-76
Test Details
DIME Sample ID: 2019-04-17-54
DIME Test ID: 2019-04-17-54-5
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2019-08-30
Test Results

How many times will the test be run?: Once
Input Type: Measured
Tester's full name: Phil Montes
Date of test: 08/14/2019
Clay reading: 7.4
Sand reading: 4.4
Sand Equivalent:60
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/30/2019