Test 2019-08-12-12-1 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 213702
DEA: 041G4304
EFIS: 0412000126
DIST-CO-RTE-PM04-NAP-128-R7.4
Work DescriptionREPLACE BRIDGE, HMA PAVING, DRAINAGE AND RSP
Location DescriptionNAPA COUNTY NEAR SAINT HELENA AT CONN CREEK
Sample Information
Sample Taken Date8/12/2019 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/12/2019
Sample typeQuality Assurance A brief description of the sampleHRC Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameHRC CMC Rebar Transportation Laboratory (TL) NumberC741450
Inspector Lot Number from the Transportation Laboratory (TL) FormB907519 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerHRC CMC Rebar Intermediate Assembler or FabricatorUnknown
Rebar Size9 Coupler ModelHRC 500 510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)351817 73113004 Rebar Heat Number(s)9000505
Rebar Size 2
Test Details
DIME Sample ID: 2019-08-12-12
DIME Test ID: 2019-08-12-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2019-08-19
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/19/2019
UTM:400kip
Temperature:72.00 f
Halo ID:Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13No. 9/29mm101100864100864OK Neckingfsaylor

General comments (publicly viewable) (Max 250 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 08/19/2019