Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2019-08-12-12

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213702
DEA: 041G4304
EFIS: 0412000126
DIST-CO-RTE-PM04-NAP-128-R7.4
Award Date03/29/2019
Closeout Date12/08/2022
Work DescriptionREPLACE BRIDGE, HMA PAVING, DRAINAGE AND RSP
Location DescriptionNAPA COUNTY NEAR SAINT HELENA AT CONN CREEK
QA Service Level1 (Verified on 07/29/2019)

Sample Information

Sample Taken Date08/12/2019 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/12/2019
Sample typeQuality Assurance A brief description of the sampleHRC Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC CMC Rebar Transportation Laboratory (TL) NumberC741450
Inspector Lot Number from the Transportation Laboratory (TL) FormB907519 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerHRC CMC Rebar Intermediate Assembler or FabricatorUnknown
Rebar Size9 Coupler ModelHRC 500 510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)351817 73113004 Rebar Heat Number(s)9000505
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-08-12-12-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/2019fsaylor
Yes
08/19/2019OK Necking
2019-08-12-12-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/2019fsaylor
Yes
08/19/2019OK Necking
2019-08-12-12-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/2019fsaylor
Yes
08/19/2019OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-08-12-12-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2019-08-12-12-2 CTM 670-December 2013 (Verified)