Summary for Test 2019-06-21-1-7
Test performed: ASTM A722-15Project Information
Project Identifiers | Project ID: 213747 DEA: 080Q9104 EFIS: 0800020580 |
---|---|
DIST-CO-RTE-PM | 08-SBD-10-R23.8 |
Award Date | 01/30/2019 |
Closeout Date | 07/27/2022 |
Work Description | RETROFIT BRIDGE PIER WALLS, FOOTINGS AND POLYESTER CONCRETE OVERLAY. |
Location Description | SAN BERNARDINO COUNTY IN COLTON AT THE SANTA ANA RIVER BRIDGES |
QA Service Level | 1 (Verified on 03/18/2019) |
Sample Information
Sample Taken Date | 06/21/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/24/2019 |
Sample type | Quality Assurance | A brief description of the sample | ATB A722 plus couplers and hardware |
The quantity of what the sample constitutes | 6 bars, 1 coupler, 6 hex nuts | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Carolina | Last name of sampler or witnessed by | Burgan |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Williams Form Engineering | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A722 | Threaded Bar Grade | 150 |
Threaded Bar Type | Rebar Size | ||
Nut Specification for Threaded Bar | Unknown | System Manufacturer | Unknown |
Epoxy Coating Color | NA | Threaded Bar Application | |
Coating Standards | Uncoated | Bar Heat Number(s) | 1000796073, 1000891061, 100891062 |
Nut Heat Number(s) | 75072337 (64D1D) | Bar Lot Number | Unknown |
Nut Lot Number | Unknown | Coupler Heat Number(s) | C158181 (64U8D) |
Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2019-06-21-1
DIME Test ID: 2019-06-21-1-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2019-07-03
Test Results
Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 07/02/2019
UTM: 2000kip
Temperature: 72 f
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 6 | ASTM A722 Type II Deformed Bar 2 1/2 : 65mm | NA | 5.16 | 157005.50 | 131.34 | 7 | 0 | Bar # 2 Heat# 100891062 Elongation | bewing |
General comments (publicly viewable) (Max 1000 characters): Bar # 2 Heat# 100891062 Elongation
Test Graph
Source: Bluehill Data Point File
WARNING: strain or stress not found in data points imported from Instron machine.
Test was verified on 7/3/2019 ✔