Owner Lab
- CT QASI - Los Angeles Field Laboratory
DIME Sample ID 2019-06-21-1
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 213747 DEA: 080Q9104 EFIS: 0800020580 |
DIST-CO-RTE-PM | 08-SBD-10-R23.8 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | RETROFIT BRIDGE PIER WALLS, FOOTINGS AND POLYESTER CONCRETE OVERLAY. |
Location Description | SAN BERNARDINO COUNTY IN COLTON AT THE SANTA ANA RIVER BRIDGES |
QA Service Level | 1 (Verified on 03/18/2019) |
Sample Information
Sample Taken Date | 06/21/2019 |
Sample Unique Key | 1 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 06/24/2019 |
Sample type | Quality Assurance |
A brief description of the sample | ATB A722 plus couplers and hardware |
The quantity of what the sample constitutes | 6 bars, 1 coupler, 6 hex nuts |
From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Carolina |
Last name of sampler or witnessed by | Burgan |
Title of sampler | |
Telephone number of sampler | |
Laboratory sample identification | |
Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Williams Form Engineering |
Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | |
Structure unique identifier | |
Structure name | |
---|
Material Information
Material Type | SMTL TM5 - Threaded Bar |
Production or Authorization Testing | Authorization Testing |
Threaded Bar Specification | ASTM A722 |
Threaded Bar Grade | 150 |
Threaded Bar Type | |
Rebar Size | |
Nut Specification for Threaded Bar | Unknown |
System Manufacturer | Unknown |
Epoxy Coating Color | NA |
Threaded Bar Application | |
Coating Standards | Uncoated |
Bar Heat Number(s) | 1000796073, 1000891061, 100891062 |
Nut Heat Number(s) | 75072337 (64D1D) |
Bar Lot Number | Unknown |
Nut Lot Number | Unknown |
Coupler Heat Number(s) | C158181 (64U8D) |
Coupler Grade | Unknown |
---|
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2019-06-21-1-1 | ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/02/2019 | bewing | Yes | 07/03/2019 | #1 Bar Heat #100891061 | |
2019-06-21-1-2 | ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/02/2019 | bewing | Yes | 07/03/2019 | #1 Bar Heat# 100891062 | |
2019-06-21-1-3 | ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/02/2019 | bewing | Yes | 07/03/2019 | Bar 3 Heat # 100891062 with Coupler Bar Broke in Grip | |
2019-06-21-1-4 | ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/02/2019 | bewing | Yes | 07/03/2019 | #1 Bar Heat #100796073 | |
2019-06-21-1-5 | ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/02/2019 | bewing | Yes | 07/03/2019 | Bar 2 Heat#100796073 Elongation | |
2019-06-21-1-6 | ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/02/2019 | bewing | Yes | 07/03/2019 | Bar 2 Heat#100891061 Elongation | |
2019-06-21-1-7 | ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/02/2019 | bewing | Yes | 07/03/2019 | Bar # 2 Heat# 100891062 Elongation | |
2019-06-21-1-8 | ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile) | bewing | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/03/2019 | bewing | Yes | 07/03/2019 | Bar 3 Heat # 100891062 with Coupler Test Only | |
6320863209632146321963220632216322263232