Summary for Test 2019-04-16-12-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 211772 DEA: 043G4624 EFIS: 0412000062 |
---|---|
DIST-CO-RTE-PM | 04-CC-680-25.0-25.4 |
Award Date | 01/04/2017 |
Closeout Date | 11/12/2019 |
Work Description | Floor Beam Mitigation at Benicia-Martinez Bridge (28-0153L) |
Location Description | Benicia-Martinez Bridge Floor Beam Mitigation Project |
QA Service Level | 1 (Verified on 09/23/2016) |
Sample Information
Sample Taken Date | 04/16/2019 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/16/2019 |
Sample type | Quality Assurance | A brief description of the sample | A325 Fasteners |
The quantity of what the sample constitutes | as per sampling table | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Richard | Last name of sampler or witnessed by | Bettencourt |
Title of sampler | QA Inspector | Telephone number of sampler | 209-201-5432 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CK Johnson Industries | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S25-064-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | R407066A-2, R350831A, R33459A, R382642A, R332919A, R321531A, R282789A, |
---|---|---|---|
Heat Number(s) | 100888940, NF14102452, NF13203760, NF16103168, NF13202676, NF12204477, NF10103192, DL17102697, DL15107150 | Nut Mfg. Lot Number(s) | 363695A,36395A,36395A, 36395A, 374243A, 374243A, 374243A, |
Washer Mfg. Lot Number(s) | C9199M, C9199M, C9199M, C9199M, 0917-628, 0917-628, 0917-628, | Bolt Specification | A325 |
Bolt Length(s) | 3",3-3/4",4-1/4",4-3/4",4-1/2" , 5-1/2", 6", | Nut Specification | DH MG |
Washer Specification | F436, | Finish | Mech Galv |
Diameter/Size | 1", 1", 1", 1", 7/8", 7/8", 7/8" | Bolt Mfg. Lot Number | 406066A, 350831A, 33459A, 382642A, 33291A, 32 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-04-16-12
DIME Test ID: 2019-04-16-12-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-05-08
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 04/30/2019
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2A | 350831A | 1\" | 91314 | 406.2 | 10 | A325 | Steve |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 5/1/2019 ✔