Sample Record

Owner Lab

  • CT HQ - QASI Sacramento Field Office

DIME Sample ID 2019-04-16-12

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211772
DEA: 043G4624
EFIS: 0412000062
DIST-CO-RTE-PM04-CC-680-25.0-25.4
Award Date01/04/2017
Closeout Date11/12/2019
Work DescriptionFloor Beam Mitigation at Benicia-Martinez Bridge (28-0153L)
Location DescriptionBenicia-Martinez Bridge Floor Beam Mitigation Project
QA Service Level1 (Verified on 09/23/2016)

Sample Information

Sample Taken Date04/16/2019 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/16/2019
Sample typeQuality Assurance A brief description of the sampleA325 Fasteners
The quantity of what the sample constitutesas per sampling table From where was the sample collectedFabricator
First name of sampler or witnessed byRichard Last name of sampler or witnessed byBettencourt
Title of samplerQA Inspector Telephone number of sampler209-201-5432
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCK Johnson Industries Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS25-064-19 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)R407066A-2, R350831A, R33459A, R382642A, R332919A, R321531A, R282789A,
Heat Number(s)100888940, NF14102452, NF13203760, NF16103168, NF13202676, NF12204477, NF10103192, DL17102697, DL15107150 Nut Mfg. Lot Number(s)363695A,36395A,36395A, 36395A, 374243A, 374243A, 374243A,
Washer Mfg. Lot Number(s)C9199M, C9199M, C9199M, C9199M, 0917-628, 0917-628, 0917-628, Bolt SpecificationA325
Bolt Length(s)3",3-3/4",4-1/4",4-3/4",4-1/2" , 5-1/2", 6", Nut SpecificationDH MG
Washer SpecificationF436, FinishMech Galv
Diameter/Size1", 1", 1", 1", 7/8", 7/8", 7/8" Bolt Mfg. Lot Number406066A, 350831A, 33459A, 382642A, 33291A, 32
Rocap Test Requirement(s) Lubricant Requirements(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2019-04-16-12-1ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory04/30/2019Steve
Yes
05/08/2019A325
2019-04-16-12-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory04/30/2019Steve
Yes
05/08/2019A325
2019-04-16-12-3ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory04/30/2019Steve
Yes
05/08/2019A325
2019-04-16-12-4ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory04/30/2019Steve
Yes
05/08/2019A325
2019-04-16-12-5ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory04/30/2019Steve
Yes
05/08/2019A325
2019-04-16-12-6ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory04/30/2019Steve
Yes
05/08/2019A325
2019-04-16-12-7ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory04/30/2019Steve
Yes
05/08/2019A325
2019-04-16-12-8ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory04/30/2019Steve
Yes
05/08/2019nut proof
2019-04-16-12-9ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Steve, CT HQ - Sacramento Structural Materials Testing Laboratory04/30/2019Steve
Yes
05/08/2019Nut Proof Load
2019-04-16-12-10ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory05/01/2019Steven Paine
Yes
05/08/2019

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2019-04-16-12-1 ASTM F606-14a (Verified)
DIME Test ID: 2019-04-16-12-2 ASTM F606-14a (Verified)
DIME Test ID: 2019-04-16-12-3 ASTM F606-14a (Verified)
DIME Test ID: 2019-04-16-12-4 ASTM F606-14a (Verified)
DIME Test ID: 2019-04-16-12-5 ASTM F606-14a (Verified)
DIME Test ID: 2019-04-16-12-6 ASTM F606-14a (Verified)
DIME Test ID: 2019-04-16-12-7 ASTM F606-14a (Verified)
DIME Test ID: 2019-04-16-12-8 ASTM F606-14a (Verified)
DIME Test ID: 2019-04-16-12-9 ASTM F606-14a (Verified)
DIME Test ID: 2019-04-16-12-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-13 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-14 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-15 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-16 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-17 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-18 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-19 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-20 ASME B1.2-83r01 (Verified)
DIME Test ID: 2019-04-16-12-21 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-22 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-23 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-24 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-25 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-26 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-27 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-28 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-29 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-30 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-31 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-32 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-33 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-34 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-35 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-36 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-37 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-38 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-39 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-40 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-41 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-42 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-43 ASTM B499-14 (Verified)
DIME Test ID: 2019-04-16-12-44 ASTM E18-15 (Verified)
DIME Test ID: 2019-04-16-12-45 ASTM E18-15 (Verified)
DIME Test ID: 2019-04-16-12-46 ASTM E18-15 (Verified)
DIME Test ID: 2019-04-16-12-47 ASTM E18-15 (Verified)
DIME Test ID: 2019-04-16-12-48 ASTM E18-15 (Verified)