Summary for Test 2019-02-04-1-7
Test performed: ASTM F606-14aProject Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/04/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/11/2019 |
Sample type | Quality Assurance | A brief description of the sample | F1554 HDG Anchor Bolt w/ Nuts & washers. |
The quantity of what the sample constitutes | 2 Lots | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | QAI | Telephone number of sampler | 3609216934 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | A and M Nut and Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-037-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Bolt Heat 3075021, 3083253 Nut Heat 178003, 75072703 Washer Heat 170921, 180231 | Nut Mfg. Lot Number(s) | 28178-178003, 29784-75072703 |
Washer Mfg. Lot Number(s) | Bolt Specification | A529-55, F1554-15 | |
Bolt Length(s) | 42" | Nut Specification | A194 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1-1/4" x 42" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-02-04-1
DIME Test ID: 2019-02-04-1-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-02-27
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/19/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 2B | 29784-75072703 | 1 1/4 \" | 172850 | 768.88 | Nut Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 2/20/2019 ✔