Summary for Test 2017-05-17-15-2

Test performed: CTM 204-June 2010

Project Information

Project IdentifiersProject ID: 212886
DEA: 023H1204
DIST-CO-RTE-PM02-TEH-5-R0.0/R22.4
Award Date01/03/2018
Closeout Date02/06/2019
Work DescriptionCOLD PLANE RAC-O, PLACE RHMA-O, REPLACE AC SURFACING, MBGR
Location DescriptionTEHAMA COUNTY AT AND NEAR CORNING FROM GLENN COUNTY LINE TO 0.3 MILE NORTH OF BRANCH COYOTE CREEK BRIDGE
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date05/17/2017 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/05/2017
Sample typeVerification A brief description of the sampleLaboratory-Combined Untreated Virgin 3/4-inch Type A Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byJoseph Last name of sampler or witnessed bySturges
Title of samplerPEI Tech Telephone number of samplerUnknown
Laboratory sample identificationD76918F Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTullis, Inc - Northstate Asphalt - Redding, CA Transportation Laboratory (TL) Number851339
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057::SHASTA RANCH AGGREGATES
The fabricator's/manufacturer's product name for the sampleCombined Virgin Aggregate The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile at the Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design number17-04-S1 Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2017-05-17-15
DIME Test ID: 2017-05-17-15-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2018-07-13

Test Results


The test method used?: Plastic Index
Input Type: Calculated
Tester's full name: Mike Cruz
Date of test: 05/05/2017
Liquid Limit (LL): 0 %
Plastic Limit (PL): 0 %
Plastic Index(PI): NP
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/13/2018