Test 2018-06-06-3-3 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 212743
DEA: 030H26U4
EFIS: 0317000247
DIST-CO-RTE-PM03-PLA-65-R5.0/R6.6
Work DescriptionNORTHBOUND WIDENING AND RAMP IMPROVEMENTS.
Location DescriptionPLACER COUNTY IN AND NEAR ROSEVILLE AND ROCKLIN FROM 0.1 MILE SOUTH OF EAST ROSEVILLE VIADUCT TO 0.5 MILE SOUTH OF PLEASANT GROVE BOULEVARD OVERCROSSING
Sample Information
Sample Taken Date6/6/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/11/2018
Sample typeAcceptance A brief description of the sampleFlash welded 7 x 10 rebar hoops
The quantity of what the sample constitutes Lot 9 150 of 600 total From where was the sample collectedFabricator
First name of sampler or witnessed byBrian Last name of sampler or witnessed byHolck
Title of samplerCALTRANS METS QA INSPECTOR Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameCMC Rebar Tracy CA Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS44-005-18 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)4074933
Hoop Manufacturer Lot Number(s)9 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop10'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCmc tracy
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2018-06-06-3
DIME Test ID: 2018-06-06-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-06-20
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/12/2018
UTM:400KIP
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
139#7/22mm0.65739095650Bar BrokeFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 06/13/2018